NEW QUESTION 133
Which humidifier is used by the NetCol 8000-A?

  • A. High pressure micro-mist humidifier
  • B. Wet film humidifier
  • C. Electrode humidifier
  • D. Infrared humidifier

Answer: D

 

NEW QUESTION 134
To use the NetEco APP on PAD to query the PUE information of the current computer room, you need to click the () menu.

  • A. Energy consumption
  • B. More
  • C. Monitoring
  • D. Alarm

Answer: A

 

NEW QUESTION 135
When calculating the battery capacity, the battery discharge capacity coefficients of the different backup times are the same.

  • A. False
  • B. True

Answer: A

 

NEW QUESTION 136
The device accesses the ECC800 monitoring system through a smart ETH socket, using the () interface of the intelligent FTH socket.

  • A. RS485
  • B. FE
  • C. PoE
  • D. AI/DI

Answer: C

 

NEW QUESTION 137
The UPS5000-E accepts an input voltage of ( ) V range.

  • A. 305-485
  • B. 140-490
  • C. 120-480
  • D. 138-485

Answer: D

 

NEW QUESTION 138
The gas fire extinguishing device is a fire extinguishing device composed of (). (Multiple choice)

  • A. Fire cylinder
  • B. Solenoid valve
  • C. Pressure switch
  • D. Sound and light alarm bell

Answer: A,B,C

 

NEW QUESTION 139
The multi-function sensor in the Fusion Module2000 modular channel can be connected to the () component.

  • A. Access control actuator
  • B. Cabinet collector
  • C. Smart ETH socket
  • D. WFi converter

Answer: C

 

NEW QUESTION 140
Check that the load switch is in the "OFF" position before powering up the URS5000.

  • A. True
  • B. False

Answer: A

 

NEW QUESTION 141
In order to implement the alarm event remote notification function on NetEco, which of the following tasks need to be set? (Multiple choice)

  • A. Set remote notification rules
  • B. Set the notification server
  • C. Set the notification content template
  • D. Set user groups

Answer: A,B,C,D

 

NEW QUESTION 142
In the battery model 6-GFM-150, 150 indicates the battery ().

  • A. Maximum capacity
  • B. Rated capacity
  • C. Minimum capacity
  • D. Actual capacity

Answer: B

 

NEW QUESTION 143
After the air conditioner is commissioned, the indoor temperature is in a reasonable state, and the suction pressure is not lower than ( ).

  • A. 7MPa
  • B. 0.7MPa
  • C. 5MPa
  • D. 6Mpa

Answer: B

 

NEW QUESTION 144
The UPS5000-E can press the battery cold start button on the bypass module without the main bypass input to start the inverter, and the system will automatically enter the battery inverter mode.

  • A. TRUE
  • B. FALSE

Answer: A

 

NEW QUESTION 145
ECC800 does not support alarm SMS notification, and remote maintenance cannot be implemented.

  • A. False
  • B. True

Answer: A

 

NEW QUESTION 146
Which of the following is not the reason why the NetCol 8000-A infrared humidifier water tray is not filled with water?

  • A. Infrared lamp damage
  • B. Inlet line valve is not open
  • C. The water injection pipe is blocked
  • D. The water pressure is abnormal

Answer: A

 

NEW QUESTION 147
ECC800 does not support historical data export.

  • A. False
  • B. True

Answer: A

 

NEW QUESTION 148
After the NetCol5000-C is set to the hot backup function, no backup machine is running, and a single unit adjusts the water valve opening according to the detected actual temperature to respond to the demand.

  • A. TRUE
  • B. FALSE

Answer: A

 

NEW QUESTION 149
......