NEW QUESTION 133
Which humidifier is used by the NetCol 8000-A?
- A. High pressure micro-mist humidifier
- B. Wet film humidifier
- C. Electrode humidifier
- D. Infrared humidifier
Answer: D
NEW QUESTION 134
To use the NetEco APP on PAD to query the PUE information of the current computer room, you need to click the () menu.
- A. Energy consumption
- B. More
- C. Monitoring
- D. Alarm
Answer: A
NEW QUESTION 135
When calculating the battery capacity, the battery discharge capacity coefficients of the different backup times are the same.
- A. False
- B. True
Answer: A
NEW QUESTION 136
The device accesses the ECC800 monitoring system through a smart ETH socket, using the () interface of the intelligent FTH socket.
- A. RS485
- B. FE
- C. PoE
- D. AI/DI
Answer: C
NEW QUESTION 137
The UPS5000-E accepts an input voltage of ( ) V range.
- A. 305-485
- B. 140-490
- C. 120-480
- D. 138-485
Answer: D
NEW QUESTION 138
The gas fire extinguishing device is a fire extinguishing device composed of (). (Multiple choice)
- A. Fire cylinder
- B. Solenoid valve
- C. Pressure switch
- D. Sound and light alarm bell
Answer: A,B,C
NEW QUESTION 139
The multi-function sensor in the Fusion Module2000 modular channel can be connected to the () component.
- A. Access control actuator
- B. Cabinet collector
- C. Smart ETH socket
- D. WFi converter
Answer: C
NEW QUESTION 140
Check that the load switch is in the "OFF" position before powering up the URS5000.
- A. True
- B. False
Answer: A
NEW QUESTION 141
In order to implement the alarm event remote notification function on NetEco, which of the following tasks need to be set? (Multiple choice)
- A. Set remote notification rules
- B. Set the notification server
- C. Set the notification content template
- D. Set user groups
Answer: A,B,C,D
NEW QUESTION 142
In the battery model 6-GFM-150, 150 indicates the battery ().
- A. Maximum capacity
- B. Rated capacity
- C. Minimum capacity
- D. Actual capacity
Answer: B
NEW QUESTION 143
After the air conditioner is commissioned, the indoor temperature is in a reasonable state, and the suction pressure is not lower than ( ).
- A. 7MPa
- B. 0.7MPa
- C. 5MPa
- D. 6Mpa
Answer: B
NEW QUESTION 144
The UPS5000-E can press the battery cold start button on the bypass module without the main bypass input to start the inverter, and the system will automatically enter the battery inverter mode.
- A. TRUE
- B. FALSE
Answer: A
NEW QUESTION 145
ECC800 does not support alarm SMS notification, and remote maintenance cannot be implemented.
- A. False
- B. True
Answer: A
NEW QUESTION 146
Which of the following is not the reason why the NetCol 8000-A infrared humidifier water tray is not filled with water?
- A. Infrared lamp damage
- B. Inlet line valve is not open
- C. The water injection pipe is blocked
- D. The water pressure is abnormal
Answer: A
NEW QUESTION 147
ECC800 does not support historical data export.
- A. False
- B. True
Answer: A
NEW QUESTION 148
After the NetCol5000-C is set to the hot backup function, no backup machine is running, and a single unit adjusts the water valve opening according to the detected actual temperature to respond to the demand.
- A. TRUE
- B. FALSE
Answer: A
NEW QUESTION 149
......